HERMA 500 Integration

You would like to integrate the HERMA 500 into your control system?
Then you have come to the right place.

 

Please select which connection you want to use and which controller manufacturer you are using. If the desired information is not available here, please contact our service department.

Interfaces and adapters overview

An overview of the interfaces of the HERMA applicators as well as available adapters can be downloaded by clicking on the button below.

HERMA 500 applicator – interfaces & adapters

HERMA 500 – Differentiation of the communication interfaces

Interface

Function

System Requirements

Integration

Important!

Comparison to HERMA 400

Web interface

 

  • Man-machine interface
  • Remote access via web browser to connect e.g. external HMI, tablet, notebook, etc.
  • 1:1 visualization of the display
  • Service interface for firmware updates and device backups
  • No internet interface
  • No real-time capable communication
  • HERMA 500 IO / IE
  • Web-enabled device with web browser installed
  • Physical connection for connection to end device
  • Integration by user
  • See instructions HERMA

 

  • IP addresses must be in the same address range
  • Know- how and authorization for Nezwerk integration necessary

 

  • HERMA 400 via RS232 to PC with HERMA 400config installed - HERMA 400 via Bluetooth to terminal device with HERMA App installed

Modbus TCP

 

  • Machine-to-machine interface (M2M)
  • Parameterization
  • Standardized interface for connection to open controllers
  • Communication between different systems via uniform Modbus TCP protocol
  • No real-time capable communication
  • HERMA 500 IO / IE with function enabling for Modbus TCP
  • Device with installed Modbus TCP client
  • Physical connection for connection with terminal device
  • Integration, Project planning and control by customer
  • HERMA introduces Modbus TCP as protocol
  • Customer programs the data exchange itself
  • Know how for interpretation and control of parameters and messages of HERMA 500
  • HERMA 400 PPS with IO interface via RS485 to gateway via Modbus TCP/IP

OPC UA

 

  • Machine-to-machine interface (M2M)
  • All parameters and messages of the HERMA 500 are visible
  • Monitoring of status information and operating parameters
  • Parameterizing
  • Control of functions, that do not have to be performed in real time
  • Standardized interface for connection to open controls (e. g. B. IPC, ERP system, CODESYS, etc. )
  • Communication between different systems via uniform OPC UA protocol
  • No real-time capable communication
  • HERMA 500 IO / IE with function enabling for OPC UA- Server
  • Control that supports OPC UA
  • Control with installed OPC UA client
  • Physical connection for connection with OPC UA client
  • Integration, Project planning and control by customer in OPC-UA client
  • No HERMA driver necessary
  • Know-how for interpretation and control of parameters and messages of HERMA 500
  • HERMA 400 PPS with IO interface via RS485 to gateway via Ethernet TCP/IP to OPC-UA server and/ or client of customer

Industrial Ethernet

Profinet Siemens

Profinet Schneider

Ethernet/IP

  • Machine-to-machine interface (M2M)
  • All parameters and messages of the HERMA 500 are visible
  • Monitoring of status information and operating parameters
  • Complete control via customer PLC
  • Closed interface with PLC-specific software and corresponding protocols (e.g. PROFINET for Siemens PLC)
  • Digital I/Os are largely not required -> reduced cabling effort
  • Realtime-capable communication
  • HERMA 500 IE with integrated IE- Board for corresponding PLC
  • protected HERMA driver for PLC
  • IE-capable PLC
  • Physical connection for connection with PLC
  • Initialization, Integration, project planning and control by customer in PLC project planning program
  • HERMA sample project can be used as a basis and simplifies integration
  • know- how for interpretation and control of parameters and messages of HERMA 500
  • HERMA driver is PLC specific and must be available
  • HERMA 400 PPS via RS485 to gateway via fieldbus to customer PLC